CFM Calculation Formula:
From: | To: |
CFM (Cubic Feet per Minute) calculation determines the required airflow capacity for bathroom exhaust fans. Proper CFM ensures adequate ventilation by removing moisture, odors, and pollutants from the bathroom space.
The calculator uses the CFM formula:
Where:
Explanation: The formula calculates the cubic feet of air that needs to be moved per minute to achieve the desired air change rate.
Details: Correct CFM calculation is essential for preventing mold growth, removing excess humidity, eliminating odors, and maintaining good indoor air quality in bathrooms.
Tips: Measure your bathroom dimensions to calculate room volume. Standard air change rates for bathrooms are typically 8-10 changes per hour. Enter both values to get the required CFM for your bathroom fan.
Q1: What is the typical air change rate for bathrooms?
A: Most building codes recommend 8-10 air changes per hour for bathroom ventilation.
Q2: How do I calculate room volume?
A: Multiply the length × width × height of your bathroom (all in feet) to get cubic feet.
Q3: What happens if CFM is too low?
A: Insufficient CFM can lead to poor ventilation, moisture buildup, mold growth, and lingering odors.
Q4: Can CFM be too high?
A: Yes, excessive CFM can create negative pressure, cause drafts, and waste energy without providing additional benefits.
Q5: Are there other factors to consider?
A: Yes, duct length, number of elbows, and fan efficiency also affect performance. Always consult manufacturer specifications.